      HAWKE ICG 653/UNIVERSAL CABLE GLANDS

      Hawke ICG 653/Universal cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

      For particular use with:-
      a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
      b) Cables that exhibit ‘cold flow’ characteristics.
      c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area.

      Hawke ICG 653/Universal cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 5.5-78.0mm outside cable diameters.

      When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

      ? Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.

      Hawke ICG 653/Universal cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

      • Flameproof Exdb
      • Increased Safety Exeb
      • Dust Extb
      • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

      HAWKE ICG 653/UNIVERSAL CABLE GLAND TECHNICAL SPECIFICATION

      1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db
      2. Certificate No’s  – baseefa06ATEX0058X and IECEx BAS 06.0015X
      3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC
      4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
      5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
      6. Deluge Protection – DTS01
      7. Operating Temperature Range  -60°C to +80°C

      CABLE GLAND SELECTION TABLE FOR HAWKE ICG 653/UNIVERSAL

      Hawke 

      Size Ref.

      Entry Thread Size Cable Acceptance Details

      ‘G’

       Compressed 

      Length

      Hexagon Dimensions
      Inner Sheath/ Cores ‘B’ Outer Sheath ‘C’ Armour/Braid
      Metric NPT *

      ‘D’ Max.

       Over Cores

      ‘E’ Max

      . Inner Sheath

      NOTE 1 Max.

       No. Of Cores

      NOTE 2 Max. 

      No. Of Cores

      Across 

      Flats

      Across

       Corners

      Standard Option Min. Max. Orientation 1 Orientation 2
      Os M20 ?” 8.9 10.0 12 6 5.5 12.0 0.8 / 1.25 0 / 0.8 67.0 24.0 26.5
      O M20 ?” 8.9 10.0 12 6 9.5 16.0 0.8 / 1.25 0 / 0.8 67.0 24.0 26.5
      A M20 ?” ?” 11.0 12.5 15 10 12.5 20.5 0.8 / 1.25 0 / 0.8 67.0 30.0 32.5
      B M25 1″ ?” 16.2 18.4 30 21 16.9 26.0 1.25 / 1.6 0 / 0.7 73.6 36.0 39.5
      C M32 1?” 1″ 21.9 24.7 42 42 22.0 33.0 1.6 / 2.0 0 / 0.7 78.0 46.0 50.5
      C2 M40 1?” 1?” 26.3 29.7 60 60 28.0 41.0 1.6 / 2.0 0 / 0.7 82.4 55.0 60.6
      D M50 2″ 1?” 37.1 41.7 80 80 36.0 52.6 1.8 / 2.5 0 / 1.0 88.7 65.0 70.8
      E M63 2?” 2″ 47.8 53.3 100 100 46.0 65.3 1.8 / 2.5 0 / 1.0 92.7 80.0 88.0
      F M75 3″ 2?” 59.0 66.2/65.3 ? 120 120 57.0 78.0 1.8 / 2.5 0 / 1.0 99.4 95.0 104.0

      CABLE GLAND MATERIAL & FINISH

      Hawke ICG 653/Universal cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

      PREPARING CABLE & GLAND FOR INSTALLING HAWKE ICG 653/UNIVERSAL
      CABLE PREPARATION

      Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’ removing all cable fillers.

      ‘I’ = 20mm for cable gland sizes Os to A ‘I’ = 25mm for cable gland sizes B to C2 ‘I’ = 32mm for cable gland sizes D to F ‘II’ to suit equipment. If required, fit shroud.

      CABLE GLAND PREPARATION

      Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).

      Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6).

      Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

      Hawke带胶泥铠装防爆格兰(ICG653/UNIV)
      Hawke代理商:上海颐品自动化科技有限公司(Hawke cable gland)
      Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱

      Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱 

    在线询盘/留言
  • 0571-87774297